Sechrist Products > Hyperbaric Oxygen Products
>
Accessories >
Pass Thu Ports and Cables, Electrical
Monitoring > Descriptions |
|
Pass-thru Ports and
Cables, Electrical
Monitoring
|
|
|
Note: Type II pass-thru
ports and cables are
much more durable and
less costly than the
older Type I pass-thru
ports and cables. Type
II pass-thru ports and
cables are standard
equipment on all new
chambers.
|
|
35243
|
Port, electrical
pass-thru. Type II for
Model 3200 Chamber
side hull (serial
number >202) |
Side hull interface
pass-thru port enables
patient monitoring
during HBO2 therapy by
allowing cables to
pass from monitor
outside Chamber
through side hull to
patient inside
Chamber. 20mm
diameter; designed for
and comes standard
with new Model 3200
Chamber; is not
interchangeable as
port for other chamber
models; use in
conjunction with
generic, unfinished
cable set #22156 and
#22157 and
transcutaneous monitor
(Radiometer TCM30
Monitor) cable set
#22193 |
|
35244 |
Port, electrical
pass-thru. Type II for
Model 2800 Chamber
door face |
Door interface
pass-thru port enables
patient monitoring
during HBO2 therapy by
allowing cables to
pass from monitor
outside Chamber
through the door to
patient inside
Chamber. 20mm
diameter; is not
interchangeable as
port for other chamber
models; use in
conjunction with
generic, unfinished
cable set #22156 and
#22157 and
transcutaneous monitor
(Radiometer TCM30
Monitor) cable set
#22193 |
|
22126 |
Port, electrical
pass-thru. Type II for
Model 2500B, 2800 &
3200 Chambers door
face |
Door interface
pass-thru port enables
patient monitoring
during HBO2 therapy by
allowing cables to
pass from monitor
outside Chamber
through the door to
patient inside
Chamber. 20mm diameter
pass-thru; use in
conjunction with
generic, unfinished
cable set #22156 and
#22157 and
transcutaneous monitor
(Radiometer TCM30
Monitor) cable set
#22193 |
|
23039 |
Port, electrical
pass-thru. Type I for
Model 3200 Chamber
side hull (serial
number <202) |
Side hull interface
pass-thru port enables
patient monitoring
during HBO2 therapy by
allowing cables to
pass from monitor
outside Chamber
through side hull to
patient inside
Chamber. ½ inch
(12.7mm) diameter; is
not interchangeable
as port for other
chamber models; use in
conjunction with
generic, unfinished
cables #HB 704s and
trancutaneous monitor
(Radiometer TCM30
Monitor) cable set
#22054 |
|
HB 260 |
Port, electrical
pass-thru. Type I for
Model 2500B Chamber
side hull |
Side hull interface
pass-thru port enables
patient monitoring
during HBO2 therapy by
allowing cables to
pass from monitor
outside Chamber
through side hull to
patient inside
Chamber. ½ inch
(12.7mm) diameter; is
not interchangeable
as port for other
chamber models; use in
conjunction with
generic, unfinished
cables #HB 704s and
trancutaneous monitor
(Radiometer TCM30
Monitor) cable set
#22054 |
|
22123 |
Port, electrical
pass-thru. Type I for
Model 3200 Chamber
side hull (serial
number >202) |
Side hull interface
pass-thru port enables
patient monitoring
during HBO2 therapy by
allowing cables to
pass from monitor
outside Chamber
through side hull to
patient inside
Chamber. ½ inch
(12.7mm) diameter; is
not interchangeable
for other chamber
models; use in
conjunction with
generic, unfinished
cables #HB 704s and
trancutaneous monitor
(Radiometer TCM30
Monitor) cable set
#22054 |
|
22156 |
Cable assembly,
electrical, exterior
Type II |
20mm diameter
unfinished exterior
electrical cables for
use with electrical
monitors whose leads
must pass through the
Chamber door to the
patient during
therapy. The
unfinished end allows
connection to an
assortment of monitor
leads and plugs. All
cable finishing must
be accomplished by a
biomedical engineer. |
|
|
HB 704s |
Cable assembly,
electrical, internal or
external, Type I |
½ inch (12.7mm) diameter
unfinished electrical
cable for use with
electrical monitors whose
leads must pass through
the Chamber side hull to
the patient during
therapy. The unfinished
end allows connection to
an assortment of monitor
leads and plugs. All cable
finishing must be
accomplished by a
biomedical engineer. |
|
22193 |
Cable set, for
transcutaneous monitor,
Type II |
20mm diameter, finished
cables connect Radiometer
TCM30 transcutaneous
monitor to pass-thru door
ports #35244, #22126 or
#35243 on the exterior of
the Chamber and connect
patient leads to pass-thru
port on the inside of the
Chamber, which allows
monitoring during HBO2
therapy. |
|
22054 |
Cable set, for
transcutaneous monitor,
Type I |
½ inch (12.7mm) diameter ,
finished cables connect
Radiometer TCM30
transcutaneous monitor to
pass-thru side hull ports
#23039 or #22123 or #HB260
on the exterior of the
Chamber and connect
patient leads to pass-thru
port on the inside of the
Chamber, which allows
monitoring during HBO2
therapy |
|
22194 |
Kit, port pass-thru with
transcutaneous monitor
cables set Type II for use
with Model 2500B, 2800,
3200 Chambers door face. |
Includes pass-thru port
#22126 and cables #22193
(see above for description
of each) |
|
20404 |
Kit, port pass-thru, with
interior and exterior
cables, Type II for Model
3200 Chamber side hull |
Includes pass-thru port
#35243 and cables #22156
and #22157 (see above
for description of each) |
|
20405 |
Kit, port pass-thru, with
interior and exterior
cables, Type I for Model
3200 Chamber side hull
(serial number >202)
|
Includes pass-thru port
#22123 and cables #HB 704s
(see above for
description of each) |
|
HB 228 |
IV Pass-thru Ports |
Door interface pass-thru
port enables patients to
continue IV fluid therapy
during HBO therapy by
allowing tubing to pass
from IV pump outside the
door to patient inside
Chamber. |
|
HB 703 |
IV Pass-thru |
Used in conjunction with
standard IV Infusion Sets
to allow the tubing to
pass through the chamber
door; reusable |
|
|
 |
|