Part #   Model   Description
35243   Port, electrical
pass-thru. Type II
for Model 3200
Chamber side hull (serial number
>202)
  Side hull interface pass-thru port enables patient monitoring during HBO2 therapy by allowing cables to pass from monitor outside Chamber through side hull to patient inside Chamber. 20mm diameter; designed for and comes standard with new Model 3200 Chamber; is not interchangeable as port for other chamber models; use in conjunction with generic, unfinished cable set #22156 and #22157 and transcutaneous monitor (Radiometer TCM30 Monitor) cable set #22193
35244
  Port, electrical
pass-thru. Type II for
Model 2800 Chamber
door face
  Door interface pass-thru port enables patient monitoring during HBO2 therapy by allowing cables to pass from monitor outside Chamber through the door to patient inside Chamber. 20mm diameter; is not interchangeable as port for other chamber models; use in conjunction with generic, unfinished cable set #22156 and #22157 and transcutaneous monitor (Radiometer TCM30 Monitor) cable set #22193
22126
  Port, electrical pass-thru. Type II for Model 2500B, 2800 & 3200 Chambers door face   Door interface pass-thru port enables patient monitoring during HBO2 therapy by allowing cables to pass from monitor outside Chamber through the door to patient inside Chamber. 20mm diameter pass-thru; use in conjunction with generic, unfinished cable set #22156 and #22157 and transcutaneous monitor (Radiometer TCM30 Monitor) cable set #22193
23039
  Port, electrical pass-thru. Type I for Model 3200 Chamber side hull (serial number <202)   Side hull interface pass-thru port enables patient monitoring during HBO2 therapy by allowing cables to pass from monitor outside Chamber through side hull to patient inside Chamber inch (12.7mm) diameter; is not interchangeable as port for other chamber models; use in conjunction with generic, unfinished cables #HB 704s and trancutaneous monitor (Radiometer TCM30 Monitor) cable set #22054
HB 260   Port, electrical pass-thru. Type I for Model 2500B Chamber side hull   Side hull interface pass-thru port enables patient monitoring during HBO2 therapy by allowing cables to pass from monitor outside Chamber through side hull to patient inside Chamber. inch (12.7mm) diameter; is not interchangeable as port for other chamber models; use in conjunction with generic, unfinished cables #HB 704s and trancutaneous monitor (Radiometer TCM30 Monitor) cable set #22054
22123   Port, electrical pass-thru. Type I for Model 3200 Chamber side hull (serial number >202)   Side hull interface pass-thru port enables patient monitoring during HBO2 therapy by allowing cables to pass from monitor outside Chamber through side hull to patient inside Chamber. inch (12.7mm) diameter; is not interchangeable for other chamber models; use in conjunction with generic, unfinished cables #HB 704s and trancutaneous monitor (Radiometer TCM30 Monitor) cable set #22054
22156   Cable assembly, electrical, exterior Type II   20mm diameter unfinished exterior electrical cables for use with electrical monitors whose leads must pass through the Chamber door to the patient during therapy. The unfinished end allows connection to an assortment of monitor leads and plugs. All cable finishing must be accomplished by a biomedical engineer.
22157   Cable assembly, electrical, interior Type II   20mm diameter unfinished interior electrical cables for use with electrical monitors whose leads must pass through the Chamber door to the patient during therapy. The unfinished end allows connection to an assortment of monitor leads and plugs. All cable finishing must be accomplished by a biomedical engineer.
HB 704s   Cable assembly, electrical, internal or external, Type I
mattress
  inch (12.7mm) diameter unfinished electrical cable for use with electrical monitors whose leads must pass through the Chamber side hull to the patient during therapy. The unfinished end allows connection to an assortment of monitor leads and plugs. All cable finishing must be accomplished by a biomedical engineer.
22193   Cable set, for transcutaneous monitor, Type II   20mm diameter, finished cables connect Radiometer TCM30 transcutaneous monitor to pass-thru door ports #35244, #22126 or #35243 on the exterior of the Chamber and connect patient leads to pass-thru port on the inside of the Chamber, which allows monitoring during HBO2 therapy.
22054   Cable set, for transcutaneous monitor, Type I   inch (12.7mm) diameter , finished cables connect Radiometer TCM30 transcutaneous monitor to pass-thru side hull ports #23039 or #22123 or #HB260 on the exterior of the Chamber and connect patient leads to pass-thru port on the inside of the Chamber, which allows monitoring during HBO2 therapy
22194   Kit, port pass-thru with transcutaneous monitor cables set Type II for use with Model 2500B, 2800, 3200 Chambers door face.   Includes pass-thru port #22126 and cables #22193 (see above for description of each)
20404   Kit, port pass-thru, with interior and exterior cables, Type II for Model 3200 Chamber side hull   Includes pass-thru port #35243 and cables #22156 and #22157 (see above for description of each)
20405   Kit, port pass-thru, with interior and exterior cables, Type I for Model 3200 Chamber side hull
(serial number >202)
  Includes pass-thru port #22123 and cables #HB 704s (see above for description of each)
HB 228   IV Pass-thru Ports   Door interface pass-thru port enables patients to continue IV fluid therapy during HBO therapy by allowing tubing to pass from IV pump outside the door to patient inside Chamber.
HB 703   IV Pass-thru   Used in conjunction with standard IV Infusion Sets to allow the tubing to pass through the chamber door; reusable