Sechrist Products ›› Respiratory Therapy Ventilators › Millennium® - the Infant / Pediatric Ventilator
From Sechrist Industries comes the Millennium® - the infant ventilator and pediatric ventilation system designed for maximum performance and user-friendly convenience. The Millennium® Infant Ventilator combines state-of-the-art electronics with the simplicity of pressure sensing technology. The result: simple, reliable ventilation for neonatal, infant, and pediatric patient requirements.

Reliable, Versatile, Simple. Neonatal Ventilation modes such as SIMV/IMV, Assist Control, and Backup ventilation in CPAP make the Millennium® Neonatal Ventilator the optimal choice in basic, reliable infant  ventilation and versatile pediatric ventilation.

What sets the Millennium® Infant Ventilator apart is the patented SmartSync™, a unique pressure sensing device that synchronizes the patient's natural breathing cycle with the neonatal ventilator. It has a maximum sensitivity of 0.10 cmH20, and a response time of 5-40 milliseconds depending upon the sensitivity settings. With this technology from a company you've known and trusted for decades, you can be certain the Millennium® Infant Ventilator and Pediatric/Neonatal Ventilation system will provide your patients with unparalleled performance.

 
Brochure in English
Brochure in Spanish
Exhalation Valves and Circuits
Humidifiers and Accessories
Monitors and Accessories
Ventilator Accessories and Parts


TECHNICAL SPECIFICATIONS

Recommended Applications
Neonatal, infant& pediatric patients < 50 Kg

Flow
2-32 lpm; flush 40 lpm

Modes of Operation
AC, SIMV/IMV, CPAP, CPAP with backup ventilation,
Standby

Inspiratory Time
0.1 to 3.0 seconds

I : E Ratio
Normal Range:
1:1.0 to 1:10 (sens. off)
1:1.0 to 1:99 (sens. on)
Inverse Range:1.0:1 to 4.0:1

Rate
2 to 150 breaths per minute

Expiratory Pressure
0 to 20 cmH2O

Inspiratory Pressure
5 to 70 cmH2O

Waveform
Tappered to square

Manual Breath
Electronically controlled, based upon the inspiratory
pressure, inspiratory time and waveform control setting

Alarms
High Inspiratory Pressure
Low/Prolonged Inspiratory Pressure
Low PEEP/Baseline Pressure
Apnea
High Respiratory Rate
Loss/Low Electrical Power
System Error/Vent Inop
Loss of Inlet Gas

 


Alarm Delay Time

3 to 15 seconds

Alam Mute
30 Seconds

Safety Pressure Relief Valve
15 to 85 cmH20

Indicators
Inspiratory Pressure
PEEP/Baseline Pressure
Calculated I:E Ratio
Mean Airway Pressure
Proximal Airway Pressure Bar Graph
Measured Respiratory Rate

Dimensions
13.5"(34.29cm)H
11"(27.94cm)W
9.5"(24.13cm)D

Weight
21 lbs (9.5kg)

Gas Consumption
14 lpm above the continuous flow setting

Power Requirements
110 to 120 VAC, 50/60 Hz
220 to 240 VAC, 50/60 Hz
100 VAC, 50/60 Hz